| 
   MANGO – DUSHERI (6 NOS.)  | 
 ||||
| 
   CORRUGATED FIBRE BOARD  | 
  
  
   CORRUGATED FIBRE BOARD  | 
  
  
   CORRUGATED FIBRE BOARD  | 
  
  
   CORRUGATED FIBRE BOARD  | 
  
 |
| 
   EXTERNAL DIMENSIONS (MM)  | 
  
  
   200 X 200 X 95  | 
  
  
   200 X 200 X 95  | 
  
  
   200 X 200 X 95  | 
  
  
   200 X 200 X 95  | 
  
 
| 
   STYLE OF BOX  | 
  
  
   RSC – 0201  | 
  
  
   TELESCOPIC – 0300  | 
  
  
   TELESCOPIC – 0306  | 
  
  
   TELESCOPIC – 0312  | 
  
 
| 
   NO. OF PLIES  | 
  
  
   3.0  | 
  
  
   LID – 3 TRAY – 3  | 
  
  
   LID – 3 TRAY – 3  | 
  
  
   LID – 3 TRAY – 3  | 
  
 
| 
   TYPE OF FLUTES  | 
  
  
   B (NARROW)  | 
  
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
 
| 
   DIRECTION OF FLUTES  | 
  
  
   VERTICAL  | 
  
  
   VERTICAL  | 
  
  
   VERTICAL  | 
  
  
   VERTICAL  | 
  
 
| 
   GRAMMAGE (G/M SQ.) OUTER TO INNER (INDICATIVE)  | 
  
  
   250/150 /150  | 
  
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
  
   LID: 250/150/150 TRAY: 250/150 /150  | 
  
 
| 
   BURST FACTOR OF PAPER (KRAFT) (MINIMUM)  | 
  
  
   20.0  | 
  
  
   20.0  | 
  
  
   20.0  | 
  
  
   20.0  | 
  
 
| 
   BURSTING STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM)  | 
  
  
   11.0  | 
  
  
   LID: 11.0 TRAY: 11.0  | 
  
  
   LID: 11.0 TRAY: 11.0  | 
  
  
   LID: 11.0 TRAY: 14.0  | 
  
 
| 
   NO. OF PIECES PER BOX  | 
  
  
   NOT MORE THAN TWO  | 
  
  
   NOT MORE THAN TWO  | 
  
  
   NOT MORE THAN TWO  | 
  
  
   NOT MORE THAN TWO  | 
  
 
| 
   MANUFACTURES JOINT  | 
  
  
   BY GLUING  | 
  
  
   BY GLUING  | 
  
  
   BY GLUING  | 
  
  
   BY GLUING  | 
  
 
| 
   EDGE CRUSH (KGF) (MIN)  | 
  
  
   38.00  | 
  
  
   38.00  | 
  
  
   38.00  | 
  
  
   38.00  | 
  
 
| 
   COMPRESSION STRENGTH OF BOX (KGF) (MINIMUM)  | 
  
  
   350  | 
  
  
   350  | 
  
  
   350  | 
  
  
   350  | 
  
 
| 
   COBB (30 MINUTES) (G/N SQ.) (MAXIMUM)  | 
  
  
   60  | 
  
  
   60  | 
  
  
   60  | 
  
  
   60  | 
  
 
| 
   NO OF VENTILATION HOLES  | 
  
  
   16.0  | 
  
  
   16.0  | 
  
  
   16.0  | 
  
  
   16.0  | 
  
 
| 
   DIAMETER (MM) OF POSITION OF HOLES I) TWO SIDES EACH II) TWO ENDS EACH III) TOP & BOTTOM EACH  | 
  
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
 
| 
   MANGO – DUSHERI (9 NOS.)  | 
 ||||
| 
   MATERIAL OF CONSTRUCTION  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
 
| 
   EXTERNAL DIMENSIONS (MM)  | 
  
   300 X 205 X 95  | 
  
   300 X 205 X 95  | 
  
   300 X 205 X 95  | 
  
   300 X 205 X 95  | 
 
| 
   STYLE OF BOX  | 
  
   RSC – 0201  | 
  
   TELESCOPIC – 0300  | 
  
   TELESCOPIC – 0306  | 
  
   TELESCOPIC – 0312  | 
 
| 
   NO. OF PLIES  | 
  
   3.0  | 
  
   LID – 3 TRAY – 3  | 
  
   LID – 3 TRAY – 3  | 
  
   LID – 3 TRAY – 3  | 
 
| 
   TYPE OF FLUTES  | 
  
   B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
 
| 
   DIRECTION OF FLUTES  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
 
| 
   GRAMMAGE (G/M SQ.) OUTER TO INNER (INDICATIVE)  | 
  
   250/150 /150  | 
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
   LID: 250/150/150 TRAY: 250/150 /150  | 
 
| 
   BURST FACTOR OF PAPER (KRAFT) (MINIMUM)  | 
  
   20.0  | 
  
   20.0  | 
  
   20.0  | 
  
   20.0  | 
 
| 
   BURSTING STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM)  | 
  
   11.0  | 
  
   LID: 11.0 TRAY: 11.0  | 
  
   LID: 11.0 TRAY: 11.0  | 
  
   LID: 11.0 TRAY: 14.0  | 
 
| 
   NO. OF PIECES PER BOX  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
 
| 
   MANUFACTURES JOINT  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
 
| 
   EDGE CRUSH (KGF) (MIN)  | 
  
   33.00  | 
  
   33.00  | 
  
   33.00  | 
  
   33.00  | 
 
| 
   COMPRESSION STRENGTH OF BOX (KGF) (MINIMUM)  | 
  
   350  | 
  
   350  | 
  
   350  | 
  
   350  | 
 
| 
   COBB (30 MINUTES) (G/N SQ.) (MAXIMUM)  | 
  
   60  | 
  
   60  | 
  
   60  | 
  
   60  | 
 
| 
   NO OF VENTILATION HOLES  | 
  
   16.0  | 
  
   16.0  | 
  
   16.0  | 
  
   16.0  | 
 
| 
   DIAMETER (MM) OF POSITION OF HOLES I) TWO SIDES EACH II) TWO ENDS EACH III) TOP & BOTTOM EACH  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
 
| 
   MANGO – DUSHERI (12 NOS.)  | 
 ||||
| 
   MATERIAL OF CONSTRUCTION  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
 
| 
   EXTERNAL DIMENSIONS (MM)  | 
  
   330 X 210 X 95  | 
  
   330 X 210 X 95  | 
  
   330 X 210 X 95  | 
  
   330 X 210 X 95  | 
 
| 
   STYLE OF BOX  | 
  
   RSC – 0201  | 
  
   TELESCOPIC – 0300  | 
  
   TELESCOPIC – 0306  | 
  
   TELESCOPIC – 0312  | 
 
| 
   NO. OF PLIES  | 
  
   5.0  | 
  
   LID – 3 TRAY – 3  | 
  
   LID – 3 TRAY – 3  | 
  
   LID – 3 TRAY – 5  | 
 
| 
   TYPE OF FLUTES  | 
  
   B/B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
 
| 
   DIRECTION OF FLUTES  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
 
| 
   GRAMMAGE (G/M SQ.) OUTER TO INNER (INDICATIVE)  | 
  
   250/120 /120/120/120  | 
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
   LID: 250/150/150 TRAY: 250/120 /120/120/120  | 
 
| 
   BURST FACTOR OF PAPER (KRAFT) (MINIMUM)  | 
  
   20.0  | 
  
   20.0  | 
  
   20.0  | 
  
   20.0  | 
 
| 
   BURSTING STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM)  | 
  
   14.0  | 
  
   LID: 11.0 TRAY: 11.0  | 
  
   LID: 11.0 TRAY: 11.0  | 
  
   LID: 11.0 TRAY: 14.0  | 
 
| 
   NO. OF PIECES PER BOX  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
 
| 
   MANUFACTURES JOINT  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
 
| 
   EDGE CRUSH (KGF) (MIN)  | 
  
   32.00  | 
  
   32.00  | 
  
   32.00  | 
  
   32.00  | 
 
| 
   COMPRESSION STRENGTH OF BOX (KGF) (MINIMUM)  | 
  
   450  | 
  
   450  | 
  
   450  | 
  
   450  | 
 
| 
   COBB (30 MINUTES) (G/N SQ.) (MAXIMUM)  | 
  
   60  | 
  
   60  | 
  
   60  | 
  
   60  | 
 
| 
   NO OF VENTILATION HOLES  | 
  
   16.0  | 
  
   16.0  | 
  
   16.0  | 
  
   16.0  | 
 
| 
   DIAMETER (MM) OF POSITION OF HOLES I) TWO SIDES EACH II) TWO ENDS EACH III) TOP & BOTTOM EACH  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
 
| 
   MANGO – DUSHERI (15 NOS.)  | 
 ||||
| 
   MATERIAL OF CONSTRUCTION  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
 
| 
   EXTERNAL DIMENSIONS (MM)  | 
  
   350 X 210 X 95  | 
  
   350 X 210 X 95  | 
  
   350 X 210 X 95  | 
  
   350 X 210 X 95  | 
 
| 
   STYLE OF BOX  | 
  
   RSC – 0201  | 
  
   TELESCOPIC – 0300  | 
  
   TELESCOPIC – 0306  | 
  
   TELESCOPIC – 0312  | 
 
| 
   NO. OF PLIES  | 
  
   5.0  | 
  
   LID – 3 TRAY – 3  | 
  
   LID – 3 TRAY – 3  | 
  
   LID – 3 TRAY – 5  | 
 
| 
   TYPE OF FLUTES  | 
  
   B/B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
 
| 
   DIRECTION OF FLUTES  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
 
| 
   GRAMMAGE (G/M SQ.) OUTER TO INNER (INDICATIVE)  | 
  
   250/120 /120/120/120  | 
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
   LID: 250/150/150 TRAY: 250/120 /120/120/120  | 
 
| 
   BURST FACTOR OF PAPER (KRAFT) (MINIMUM)  | 
  
   20.0  | 
  
   20.0  | 
  
   20.0  | 
  
   20.0  | 
 
| 
   BURSTING STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM)  | 
  
   14.0  | 
  
   LID: 11.0 TRAY: 11.0  | 
  
   LID: 11.0 TRAY: 11.0  | 
  
   LID: 11.0 TRAY: 14.0  | 
 
| 
   NO. OF PIECES PER BOX  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
 
| 
   MANUFACTURES JOINT  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
 
| 
   EDGE CRUSH (KGF) (MIN)  | 
  
   32.00  | 
  
   32.00  | 
  
   32.00  | 
  
   32.00  | 
 
| 
   COMPRESSION STRENGTH OF BOX (KGF) (MINIMUM)  | 
  
   450  | 
  
   450  | 
  
   450  | 
  
   450  | 
 
| 
   COBB (30 MINUTES) (G/N SQ.) (MAXIMUM)  | 
  
   60  | 
  
   60  | 
  
   60  | 
  
   60  | 
 
| 
   NO OF VENTILATION HOLES  | 
  
   16.0  | 
  
   16.0  | 
  
   16.0  | 
  
   16.0  | 
 
| 
   DIAMETER (MM) OF POSITION OF HOLES I) TWO SIDES EACH II) TWO ENDS EACH III) TOP & BOTTOM EACH  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
 
| 
   MANGO – DUSHERI (18 NOS.)  | 
 ||||
| 
   MATERIAL OF CONSTRUCTION  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
  
   CORRUGATED FIBRE BOARD  | 
 
| 
   EXTERNAL DIMENSIONS (MM)  | 
  
   420 X 220 X 95  | 
  
   420 X 220 X 95  | 
  
   420 X 220 X 95  | 
  
   420 X 220 X 95  | 
 
| 
   STYLE OF BOX  | 
  
   RSC – 0201  | 
  
   TELESCOPIC – 0300  | 
  
   TELESCOPIC – 0306  | 
  
   TELESCOPIC – 0312  | 
 
| 
   NO. OF PLIES  | 
  
   5.0  | 
  
   LID – 3 TRAY – 3  | 
  
   LID – 3 TRAY – 3  | 
  
   LID – 3 TRAY – 5  | 
 
| 
   TYPE OF FLUTES  | 
  
   B/B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
  
   LID B (NARROW) TRAY B (NARROW)  | 
 
| 
   DIRECTION OF FLUTES  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
  
   VERTICAL  | 
 
| 
   GRAMMAGE (G/M SQ.) OUTER TO INNER (INDICATIVE)  | 
  
   250/120 /120/120/120  | 
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
   LID: 250/150/150 TRAY: 250/150/150  | 
  
   LID: 250/150/150 TRAY: 250/120 /120/120/120  | 
 
| 
   BURST FACTOR OF PAPER (KRAFT) (MINIMUM)  | 
  
   20.0  | 
  
   20.0  | 
  
   20.0  | 
  
   20.0  | 
 
| 
   BURSTING STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM)  | 
  
   14.0  | 
  
   LID: 11.0 TRAY: 11.0  | 
  
   LID: 11.0 TRAY: 11.0  | 
  
   LID: 11.0 TRAY: 14.0  | 
 
| 
   NO. OF PIECES PER BOX  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
  
   NOT MORE THAN TWO  | 
 
| 
   MANUFACTURES JOINT  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
  
   BY GLUING  | 
 
| 
   EDGE CRUSH (KGF) (MIN)  | 
  
   32.00  | 
  
   32.00  | 
  
   32.00  | 
  
   32.00  | 
 
| 
   COMPRESSION STRENGTH OF BOX (KGF) (MINIMUM)  | 
  
   450  | 
  
   450  | 
  
   450  | 
  
   450  | 
 
| 
   COBB (30 MINUTES) (G/N SQ.) (MAXIMUM)  | 
  
   60  | 
  
   60  | 
  
   60  | 
  
   60  | 
 
| 
   NO OF VENTILATION HOLES  | 
  
   16.0  | 
  
   16.0  | 
  
   16.0  | 
  
   16.0  | 
 
| 
   DIAMETER (MM) OF POSITION OF HOLES I) TWO SIDES EACH II) TWO ENDS EACH III) TOP & BOTTOM EACH  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
  
   20.0 
 A) 3 B) 1 C) 4  | 
 
