BABY CORN (2 KG) |
||||
CORRUGATED FIBRE BOARD |
CORRUGATED FIBRE BOARD |
CORRUGATED FIBRE BOARD |
CORRUGATED FIBRE BOARD |
|
EXTERNAL DIMENSIONS (MM) |
300 X 200 X 90 |
300 X 200 X 90 |
300 X 200 X 90 |
300 X 200 X 90 |
STYLE OF BOX |
RSC – 0201 |
TELESCOPIC – 0300 |
TELESCOPIC – 0306 |
TELESCOPIC – 0312 |
NO. OF PLIES |
3.0 |
LID – 3 TRAY – 3 |
LID – 3 TRAY – 3 |
LID – 3 TRAY – 3 |
TYPE OF FLUTES |
B (NARROW) |
LID B (NARROW) TRAY B (NARROW) |
LID B (NARROW) TRAY B (NARROW) |
LID B (NARROW) TRAY B (NARROW) |
DIRECTION OF FLUTES |
VERTICAL |
VERTICAL |
VERTICAL |
VERTICAL |
GRAMMAGE (G/M SQ.) OUTER TO INNER (INDICATIVE) |
250 / 150 / 150 |
LID: 250/150/150 TRAY: 250/150/150 |
LID: 250/150/150 TRAY: 250/150/150 |
LID: 250/150/150 TRAY: 250/150/150 |
BURST FACTOR OF PAPER (KRAFT) (MINIMUM) |
20.0 |
20.0 |
20.0 |
20.0 |
BURSTING STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM) |
11.0 |
LID: 11.0 TRAY: 11.0 |
LID: 11.0 TRAY: 11.0 |
LID: 11.0 TRAY: 11.0 |
NO. OF PIECES PER BOX |
NOT MORE THAN TWO |
NOT MORE THAN TWO |
NOT MORE THAN TWO |
NOT MORE THAN TWO |
MANUFACTURES JOINT |
BY GLUING |
BY GLUING |
BY GLUING |
BY GLUING |
EDGE CRUSH (KGF) (MIN) |
48.00 |
48.00 |
48.00 |
48.00 |
COMPRESSION STRENGTH OF BOX (KGF) (MINIMUM) |
350 |
350 |
350 |
350 |
COBB (30 MINUTES) (G/N SQ.) (MAXIMUM) |
60 |
60 |
60 |
60 |
NO OF VENTILATION HOLES |
16.0 |
16.0 |
16.0 |
16.0 |
|
|
|
|
|
DIAMETER (MM) OF POSITION OF HOLES i) TWO SIDES EACH ii) TWO ENDS EACH iii) TOP & BOTTOM EACH |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |
BABY CORN (4 KG) |
||||
MATERIAL OF CONSTRUCTION |
CORRUGATED FIBRE BOARD |
CORRUGATED FIBRE BOARD |
CORRUGATED FIBRE BOARD |
CORRUGATED FIBRE BOARD |
EXTERNAL DIMENSIONS (MM) |
400 X 300 X 125 |
400 X 300 X 125 |
400 X 300 X 125 |
400 X 300 X 125 |
STYLE OF BOX |
RSC – 0201 |
TELESCOPIC – 0300 |
TELESCOPIC – 0306 |
TELESCOPIC – 0312 |
NO. OF PLIES |
3.0 |
LID – 3 TRAY – 3 |
LID – 3 TRAY – 3 |
LID – 3 TRAY – 3 |
TYPE OF FLUTES |
B (NARROW) |
LID B (NARROW) TRAY B (NARROW) |
LID B (NARROW) TRAY B (NARROW) |
LID B (NARROW) TRAY B (NARROW) |
DIRECTION OF FLUTES |
VERTICAL |
VERTICAL |
VERTICAL |
VERTICAL |
GRAMMAGE (G/M SQ.) OUTER TO INNER (INDICATIVE) |
250 / 150 / 150 |
LID: 250/150/150 TRAY: 250/150/150 |
LID: 250/150/150 TRAY: 250/150/150 |
LID: 250/150/150 TRAY: 250/150/150 |
BURST FACTOR OF PAPER (KRAFT) (MINIMUM) |
20.0 |
20.0 |
20.0 |
20.0 |
BURSTING STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM) |
11.0 |
LID: 11.0 TRAY: 11.0 |
LID: 11.0 TRAY: 11.0 |
LID: 11.0 TRAY: 11.0 |
NO. OF PIECES PER BOX |
NOT MORE THAN TWO |
NOT MORE THAN TWO |
NOT MORE THAN TWO |
NOT MORE THAN TWO |
MANUFACTURES JOINT |
BY GLUING |
BY GLUING |
BY GLUING |
BY GLUING |
EDGE CRUSH (KGF) (MIN) |
34.00 |
34.00 |
34.00 |
34.00 |
COMPRESSION STRENGTH OF BOX (KGF) (MINIMUM) |
350 |
350 |
350 |
350 |
COBB (30 MINUTES) (G/N SQ.) (MAXIMUM) |
60 |
60 |
60 |
60 |
NO OF VENTILATION HOLES |
16.0 |
16.0 |
16.0 |
16.0 |
DIAMETER (MM) OF POSITION OF HOLES i) TWO SIDES EACH ii) TWO ENDS EACH iii) TOP & BOTTOM EACH |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |