BABY
CORN (2 KG) |
||||
CORRUGATED
FIBRE BOARD |
CORRUGATED
FIBRE BOARD |
CORRUGATED
FIBRE BOARD |
CORRUGATED
FIBRE BOARD |
|
EXTERNAL
DIMENSIONS (MM) |
300 X
200 X 90 |
300 X
200 X 90 |
300 X
200 X 90 |
300 X
200 X 90 |
STYLE
OF BOX |
RSC –
0201 |
TELESCOPIC
– 0300 |
TELESCOPIC
– 0306 |
TELESCOPIC
– 0312 |
NO.
OF PLIES |
3.0 |
LID –
3 TRAY – 3 |
LID –
3 TRAY – 3 |
LID –
3 TRAY – 3 |
TYPE
OF FLUTES |
B
(NARROW) |
LID B
(NARROW) TRAY B (NARROW) |
LID B
(NARROW) TRAY B (NARROW) |
LID B
(NARROW) TRAY B (NARROW) |
DIRECTION
OF FLUTES |
VERTICAL |
VERTICAL |
VERTICAL |
VERTICAL |
GRAMMAGE
(G/M SQ.) OUTER TO INNER (INDICATIVE) |
250 /
150 / 150 |
LID:
250/150/150 TRAY:
250/150/150 |
LID:
250/150/150 TRAY:
250/150/150 |
LID:
250/150/150 TRAY:
250/150/150 |
BURST
FACTOR OF PAPER (KRAFT) (MINIMUM) |
20.0 |
20.0 |
20.0 |
20.0 |
BURSTING
STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM) |
11.0 |
LID:
11.0 TRAY:
11.0 |
LID:
11.0 TRAY:
11.0 |
LID:
11.0 TRAY:
11.0 |
NO.
OF PIECES PER BOX |
NOT
MORE THAN TWO |
NOT
MORE THAN TWO |
NOT
MORE THAN TWO |
NOT
MORE THAN TWO |
MANUFACTURES
JOINT |
BY
GLUING |
BY
GLUING |
BY
GLUING |
BY
GLUING |
EDGE
CRUSH (KGF) (MIN) |
48.00 |
48.00 |
48.00 |
48.00 |
COMPRESSION
STRENGTH OF BOX (KGF) (MINIMUM) |
350 |
350 |
350 |
350 |
COBB
(30 MINUTES) (G/N SQ.) (MAXIMUM) |
60 |
60 |
60 |
60 |
NO OF
VENTILATION HOLES |
16.0 |
16.0 |
16.0 |
16.0 |
|
|
|
|
|
DIAMETER
(MM) OF POSITION OF HOLES i) TWO SIDES EACH ii) TWO ENDS EACH iii) TOP & BOTTOM
EACH |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |
20.0
a) 3 b) 1 c) 4 |
BABY
CORN (4 KG) |
||||
MATERIAL
OF CONSTRUCTION |
CORRUGATED
FIBRE BOARD |
CORRUGATED
FIBRE BOARD |
CORRUGATED
FIBRE BOARD |
CORRUGATED
FIBRE BOARD |
EXTERNAL
DIMENSIONS (MM) |
400
X 300 X 125 |
400
X 300 X 125 |
400
X 300 X 125 |
400
X 300 X 125 |
STYLE
OF BOX |
RSC
– 0201 |
TELESCOPIC
– 0300 |
TELESCOPIC
– 0306 |
TELESCOPIC
– 0312 |
NO.
OF PLIES |
3.0 |
LID
– 3 TRAY – 3 |
LID
– 3 TRAY – 3 |
LID
– 3 TRAY – 3 |
TYPE
OF FLUTES |
B
(NARROW) |
LID
B (NARROW) TRAY B (NARROW) |
LID
B (NARROW) TRAY B (NARROW) |
LID
B (NARROW) TRAY B (NARROW) |
DIRECTION
OF FLUTES |
VERTICAL |
VERTICAL |
VERTICAL |
VERTICAL |
GRAMMAGE
(G/M SQ.) OUTER TO INNER (INDICATIVE) |
250
/ 150 / 150 |
LID:
250/150/150 TRAY:
250/150/150 |
LID:
250/150/150 TRAY:
250/150/150 |
LID:
250/150/150 TRAY:
250/150/150 |
BURST
FACTOR OF PAPER (KRAFT) (MINIMUM) |
20.0 |
20.0 |
20.0 |
20.0 |
BURSTING
STRENGTH OF BOARD (KG/CM. SQ) (MINIMUM) |
11.0 |
LID:
11.0 TRAY:
11.0 |
LID:
11.0 TRAY:
11.0 |
LID:
11.0 TRAY:
11.0 |
NO.
OF PIECES PER BOX |
NOT
MORE THAN TWO |
NOT
MORE THAN TWO |
NOT
MORE THAN TWO |
NOT
MORE THAN TWO |
MANUFACTURES
JOINT |
BY
GLUING |
BY
GLUING |
BY
GLUING |
BY
GLUING |
EDGE
CRUSH (KGF) (MIN) |
34.00 |
34.00 |
34.00 |
34.00 |
COMPRESSION
STRENGTH OF BOX (KGF) (MINIMUM) |
350 |
350 |
350 |
350 |
COBB
(30 MINUTES) (G/N SQ.) (MAXIMUM) |
60 |
60 |
60 |
60 |
NO
OF VENTILATION HOLES |
16.0 |
16.0 |
16.0 |
16.0 |
DIAMETER
(MM) OF POSITION OF HOLES i)
TWO SIDES EACH ii)
TWO ENDS EACH iii)
TOP & BOTTOM EACH |
20.0
a) 3 b) 1 c)
4 |
20.0
a) 3 b) 1 c)
4 |
20.0
a) 3 b) 1 c)
4 |
20.0
a) 3 b) 1 c)
4 |